An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4

Wenwen Lin, Oleg Y. Kontsevoi, Zhifu Liu, Sanjib Das, Yihui He, Yadong Xu, Constantinos C. Stoumpos, Kyle M. McCall, Alexander J.E. Rettie, Duck Young Chung, Bruce W. Wessels, Mercouri G Kanatzidis

Research output: Contribution to journalArticle

Abstract

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6SeI4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TlI. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 1011 ω·cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV γ-ray from 57Co radiation source. The electron mobility-lifetime product μeτe for Tl6SeI4 detector is 8.1 × 10-5 cm2·V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV α-particles from 241Am, the electron and hole mobilities were estimated to be 112 ± 22 and 81 ± 16 cm2·V-1·s-1, respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Original languageEnglish
Pages (from-to)3484-3493
Number of pages10
JournalCrystal Growth and Design
Volume18
Issue number6
DOIs
Publication statusPublished - Jun 6 2018

Fingerprint

nuclear radiation
Radiation detectors
radiation detectors
purification
Purification
Impurities
impurities
Detectors
detectors
Electron mobility
electron mobility
Radiation
Semiconductor materials
photopeak
Defects
Crystals
Crystal growth from melt
Hole mobility
Bridgman method
Carrier transport

ASJC Scopus subject areas

  • Chemistry(all)
  • Materials Science(all)
  • Condensed Matter Physics

Cite this

An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4. / Lin, Wenwen; Kontsevoi, Oleg Y.; Liu, Zhifu; Das, Sanjib; He, Yihui; Xu, Yadong; Stoumpos, Constantinos C.; McCall, Kyle M.; Rettie, Alexander J.E.; Chung, Duck Young; Wessels, Bruce W.; Kanatzidis, Mercouri G.

In: Crystal Growth and Design, Vol. 18, No. 6, 06.06.2018, p. 3484-3493.

Research output: Contribution to journalArticle

Lin, W, Kontsevoi, OY, Liu, Z, Das, S, He, Y, Xu, Y, Stoumpos, CC, McCall, KM, Rettie, AJE, Chung, DY, Wessels, BW & Kanatzidis, MG 2018, 'An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4', Crystal Growth and Design, vol. 18, no. 6, pp. 3484-3493. https://doi.org/10.1021/acs.cgd.8b00242
Lin, Wenwen ; Kontsevoi, Oleg Y. ; Liu, Zhifu ; Das, Sanjib ; He, Yihui ; Xu, Yadong ; Stoumpos, Constantinos C. ; McCall, Kyle M. ; Rettie, Alexander J.E. ; Chung, Duck Young ; Wessels, Bruce W. ; Kanatzidis, Mercouri G. / An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4. In: Crystal Growth and Design. 2018 ; Vol. 18, No. 6. pp. 3484-3493.
@article{be668f1939c64b10b46b97907637e938,
title = "An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4",
abstract = "The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6SeI4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TlI. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 1011 ω·cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV γ-ray from 57Co radiation source. The electron mobility-lifetime product μeτe for Tl6SeI4 detector is 8.1 × 10-5 cm2·V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV α-particles from 241Am, the electron and hole mobilities were estimated to be 112 ± 22 and 81 ± 16 cm2·V-1·s-1, respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.",
author = "Wenwen Lin and Kontsevoi, {Oleg Y.} and Zhifu Liu and Sanjib Das and Yihui He and Yadong Xu and Stoumpos, {Constantinos C.} and McCall, {Kyle M.} and Rettie, {Alexander J.E.} and Chung, {Duck Young} and Wessels, {Bruce W.} and Kanatzidis, {Mercouri G}",
year = "2018",
month = "6",
day = "6",
doi = "10.1021/acs.cgd.8b00242",
language = "English",
volume = "18",
pages = "3484--3493",
journal = "Crystal Growth and Design",
issn = "1528-7483",
publisher = "American Chemical Society",
number = "6",

}

TY - JOUR

T1 - An Effective Purification Process for the Nuclear Radiation Detector Tl6SeI4

AU - Lin, Wenwen

AU - Kontsevoi, Oleg Y.

AU - Liu, Zhifu

AU - Das, Sanjib

AU - He, Yihui

AU - Xu, Yadong

AU - Stoumpos, Constantinos C.

AU - McCall, Kyle M.

AU - Rettie, Alexander J.E.

AU - Chung, Duck Young

AU - Wessels, Bruce W.

AU - Kanatzidis, Mercouri G

PY - 2018/6/6

Y1 - 2018/6/6

N2 - The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6SeI4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TlI. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 1011 ω·cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV γ-ray from 57Co radiation source. The electron mobility-lifetime product μeτe for Tl6SeI4 detector is 8.1 × 10-5 cm2·V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV α-particles from 241Am, the electron and hole mobilities were estimated to be 112 ± 22 and 81 ± 16 cm2·V-1·s-1, respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

AB - The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6SeI4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TlI. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 1011 ω·cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV γ-ray from 57Co radiation source. The electron mobility-lifetime product μeτe for Tl6SeI4 detector is 8.1 × 10-5 cm2·V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV α-particles from 241Am, the electron and hole mobilities were estimated to be 112 ± 22 and 81 ± 16 cm2·V-1·s-1, respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

UR - http://www.scopus.com/inward/record.url?scp=85046470018&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85046470018&partnerID=8YFLogxK

U2 - 10.1021/acs.cgd.8b00242

DO - 10.1021/acs.cgd.8b00242

M3 - Article

VL - 18

SP - 3484

EP - 3493

JO - Crystal Growth and Design

JF - Crystal Growth and Design

SN - 1528-7483

IS - 6

ER -