Carbon nanotube-based electrodes for detection of low-ppb level hexavalent chromium using amperometry

Chengwei Wang, Candace Chan

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Carbon nanotube (CNT)-based electrodes, prepared using a printable technique,were investigated for the electrochemical detection of hexavalent chromium (Cr(VI)). CNT pastes were coated onto paper substrates and commercially available screen-printed electrodes and used as amperometric sensors for Cr(VI). The CNT electrodes showed electrochemical current responses as high as 500 nA/ppb Cr(VI) and limit of detection as low as 5 ppb when a large area electrode was used. The CNT-modified, screen-printed electrodes showed good selectivity to Cr(VI) and were effective for quantifying the Cr(VI) levels in cooling tower blowdown water. A selective H2O2 reduction technique was also applied to Cr(VI) detection and integrated into amperometric detection in a flow cell. These studies show that CNT-based electrodes can be promising for field applications and real-time monitoring of low-level Cr(VI) in power plant waters.

Original languageEnglish
Pages (from-to)M3026-M3031
JournalECS Journal of Solid State Science and Technology
Volume5
Issue number8
DOIs
Publication statusPublished - 2016

Fingerprint

Carbon Nanotubes
Chromium
Carbon nanotubes
Electrodes
Water cooling towers
Electrochemical electrodes
Amperometric sensors
Power plants
chromium hexavalent ion
Ointments
Monitoring
Substrates
Water

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials

Cite this

Carbon nanotube-based electrodes for detection of low-ppb level hexavalent chromium using amperometry. / Wang, Chengwei; Chan, Candace.

In: ECS Journal of Solid State Science and Technology, Vol. 5, No. 8, 2016, p. M3026-M3031.

Research output: Contribution to journalArticle

@article{eed7b785ab0b4d9db799101f62bcfc3b,
title = "Carbon nanotube-based electrodes for detection of low-ppb level hexavalent chromium using amperometry",
abstract = "Carbon nanotube (CNT)-based electrodes, prepared using a printable technique,were investigated for the electrochemical detection of hexavalent chromium (Cr(VI)). CNT pastes were coated onto paper substrates and commercially available screen-printed electrodes and used as amperometric sensors for Cr(VI). The CNT electrodes showed electrochemical current responses as high as 500 nA/ppb Cr(VI) and limit of detection as low as 5 ppb when a large area electrode was used. The CNT-modified, screen-printed electrodes showed good selectivity to Cr(VI) and were effective for quantifying the Cr(VI) levels in cooling tower blowdown water. A selective H2O2 reduction technique was also applied to Cr(VI) detection and integrated into amperometric detection in a flow cell. These studies show that CNT-based electrodes can be promising for field applications and real-time monitoring of low-level Cr(VI) in power plant waters.",
author = "Chengwei Wang and Candace Chan",
year = "2016",
doi = "10.1149/2.0051608jss",
language = "English",
volume = "5",
pages = "M3026--M3031",
journal = "ECS Journal of Solid State Science and Technology",
issn = "2162-8769",
publisher = "Electrochemical Society, Inc.",
number = "8",

}

TY - JOUR

T1 - Carbon nanotube-based electrodes for detection of low-ppb level hexavalent chromium using amperometry

AU - Wang, Chengwei

AU - Chan, Candace

PY - 2016

Y1 - 2016

N2 - Carbon nanotube (CNT)-based electrodes, prepared using a printable technique,were investigated for the electrochemical detection of hexavalent chromium (Cr(VI)). CNT pastes were coated onto paper substrates and commercially available screen-printed electrodes and used as amperometric sensors for Cr(VI). The CNT electrodes showed electrochemical current responses as high as 500 nA/ppb Cr(VI) and limit of detection as low as 5 ppb when a large area electrode was used. The CNT-modified, screen-printed electrodes showed good selectivity to Cr(VI) and were effective for quantifying the Cr(VI) levels in cooling tower blowdown water. A selective H2O2 reduction technique was also applied to Cr(VI) detection and integrated into amperometric detection in a flow cell. These studies show that CNT-based electrodes can be promising for field applications and real-time monitoring of low-level Cr(VI) in power plant waters.

AB - Carbon nanotube (CNT)-based electrodes, prepared using a printable technique,were investigated for the electrochemical detection of hexavalent chromium (Cr(VI)). CNT pastes were coated onto paper substrates and commercially available screen-printed electrodes and used as amperometric sensors for Cr(VI). The CNT electrodes showed electrochemical current responses as high as 500 nA/ppb Cr(VI) and limit of detection as low as 5 ppb when a large area electrode was used. The CNT-modified, screen-printed electrodes showed good selectivity to Cr(VI) and were effective for quantifying the Cr(VI) levels in cooling tower blowdown water. A selective H2O2 reduction technique was also applied to Cr(VI) detection and integrated into amperometric detection in a flow cell. These studies show that CNT-based electrodes can be promising for field applications and real-time monitoring of low-level Cr(VI) in power plant waters.

UR - http://www.scopus.com/inward/record.url?scp=84978123752&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84978123752&partnerID=8YFLogxK

U2 - 10.1149/2.0051608jss

DO - 10.1149/2.0051608jss

M3 - Article

VL - 5

SP - M3026-M3031

JO - ECS Journal of Solid State Science and Technology

JF - ECS Journal of Solid State Science and Technology

SN - 2162-8769

IS - 8

ER -