Charge transfer in donor-bridge-acceptor systems

Static disorder, dynamic fluctuations, and complex kinetics

Yuri A. Berlin, Ferdinand C. Grozema, Laurens D A Siebbeles, Mark A Ratner

Research output: Contribution to journalArticle

87 Citations (Scopus)

Abstract

The influence of static and dynamic torsional disorder on the kinetics of charge transfer (CT) in donorbridge-acceptor (D-B-A) systems has been investigated theoretically using a simple tight-binding model. In such systems, variations of the torsion angle often give rise either to static changes in the magnitude of electronic coupling along the bridge length or to dynamic fluctuations of this quantity on the certain characteristic time scale τrot. These lead to the functional breakdown of the Condon approximation. Modeling of CT beyond the Condon approximation reveals two types of non-Condon (NC) effects. If τrot is much less than the characteristic time, τCT of CT in the absence of disorder, the NC effects was shown to be static. Due to self-averaging of electronic coupling in this fast fluctuation limit, the breakdown of the Condon approximation manifests itself as a static correction to the time-independent rate coefficient calculated for the ordered bridge with the same time-averaged electronic coupling for all pairs of adjacent subunits. As a consequence, the CT process exponentially evolves with time and therefore can be characterized by a time-independent rate coefficient wa for the charge arrival on the acceptor (also termed the rate constant). For larger τrot, however, the NC effects become purely kinetic. In this case, the process of CT in the tunneling regime exhibits time scale invariance, the corresponding decay curves become dispersive, and the rate coefficient wa turns out to be time dependent. In the limit of very slow dynamic fluctuations, where τrot ≫ τCT, the NC effects in kinetics of CT are found (as anticipated) to be very similar to the effects revealed for bridges with the static torsional disorder. Both analytical and numerical results obtained within this limit allow the conclusion that for very slow fluctuations and/or for static disorder, the nonexponential time evolution of the CT process is due to the configuration averaging of electronic coupling. Several consequences of our theoretical findings for the interpretation of experimentally observed transients are briefly discussed. In particular, we argue that the minimal value of the falloff parameter describing the distance dependence of the time-independent rate coefficient in tunneling regime can not be less than 0.2-0.3 Å-1 and that the smaller experimental value of this parameter reported in the literature for several D-B-A systems must be attributed to the multistep hopping mechanism of charge motion rather than to the mechanism of single-step tunneling.

Original languageEnglish
Pages (from-to)10988-11000
Number of pages13
JournalJournal of Physical Chemistry C
Volume112
Issue number29
DOIs
Publication statusPublished - Jul 24 2008

Fingerprint

Charge transfer
charge transfer
disorders
Kinetics
kinetics
coefficients
electronics
breakdown
approximation
Invariance
Torsional stress
Rate constants
torsion
arrivals
invariance
decay
curves
configurations

ASJC Scopus subject areas

  • Physical and Theoretical Chemistry
  • Electronic, Optical and Magnetic Materials
  • Surfaces, Coatings and Films
  • Energy(all)

Cite this

Charge transfer in donor-bridge-acceptor systems : Static disorder, dynamic fluctuations, and complex kinetics. / Berlin, Yuri A.; Grozema, Ferdinand C.; Siebbeles, Laurens D A; Ratner, Mark A.

In: Journal of Physical Chemistry C, Vol. 112, No. 29, 24.07.2008, p. 10988-11000.

Research output: Contribution to journalArticle

Berlin, Yuri A. ; Grozema, Ferdinand C. ; Siebbeles, Laurens D A ; Ratner, Mark A. / Charge transfer in donor-bridge-acceptor systems : Static disorder, dynamic fluctuations, and complex kinetics. In: Journal of Physical Chemistry C. 2008 ; Vol. 112, No. 29. pp. 10988-11000.
@article{fe97a969785646ffb204cc9f88a92cee,
title = "Charge transfer in donor-bridge-acceptor systems: Static disorder, dynamic fluctuations, and complex kinetics",
abstract = "The influence of static and dynamic torsional disorder on the kinetics of charge transfer (CT) in donorbridge-acceptor (D-B-A) systems has been investigated theoretically using a simple tight-binding model. In such systems, variations of the torsion angle often give rise either to static changes in the magnitude of electronic coupling along the bridge length or to dynamic fluctuations of this quantity on the certain characteristic time scale τrot. These lead to the functional breakdown of the Condon approximation. Modeling of CT beyond the Condon approximation reveals two types of non-Condon (NC) effects. If τrot is much less than the characteristic time, τCT of CT in the absence of disorder, the NC effects was shown to be static. Due to self-averaging of electronic coupling in this fast fluctuation limit, the breakdown of the Condon approximation manifests itself as a static correction to the time-independent rate coefficient calculated for the ordered bridge with the same time-averaged electronic coupling for all pairs of adjacent subunits. As a consequence, the CT process exponentially evolves with time and therefore can be characterized by a time-independent rate coefficient wa for the charge arrival on the acceptor (also termed the rate constant). For larger τrot, however, the NC effects become purely kinetic. In this case, the process of CT in the tunneling regime exhibits time scale invariance, the corresponding decay curves become dispersive, and the rate coefficient wa turns out to be time dependent. In the limit of very slow dynamic fluctuations, where τrot ≫ τCT, the NC effects in kinetics of CT are found (as anticipated) to be very similar to the effects revealed for bridges with the static torsional disorder. Both analytical and numerical results obtained within this limit allow the conclusion that for very slow fluctuations and/or for static disorder, the nonexponential time evolution of the CT process is due to the configuration averaging of electronic coupling. Several consequences of our theoretical findings for the interpretation of experimentally observed transients are briefly discussed. In particular, we argue that the minimal value of the falloff parameter describing the distance dependence of the time-independent rate coefficient in tunneling regime can not be less than 0.2-0.3 {\AA}-1 and that the smaller experimental value of this parameter reported in the literature for several D-B-A systems must be attributed to the multistep hopping mechanism of charge motion rather than to the mechanism of single-step tunneling.",
author = "Berlin, {Yuri A.} and Grozema, {Ferdinand C.} and Siebbeles, {Laurens D A} and Ratner, {Mark A}",
year = "2008",
month = "7",
day = "24",
doi = "10.1021/jp801646g",
language = "English",
volume = "112",
pages = "10988--11000",
journal = "Journal of Physical Chemistry C",
issn = "1932-7447",
publisher = "American Chemical Society",
number = "29",

}

TY - JOUR

T1 - Charge transfer in donor-bridge-acceptor systems

T2 - Static disorder, dynamic fluctuations, and complex kinetics

AU - Berlin, Yuri A.

AU - Grozema, Ferdinand C.

AU - Siebbeles, Laurens D A

AU - Ratner, Mark A

PY - 2008/7/24

Y1 - 2008/7/24

N2 - The influence of static and dynamic torsional disorder on the kinetics of charge transfer (CT) in donorbridge-acceptor (D-B-A) systems has been investigated theoretically using a simple tight-binding model. In such systems, variations of the torsion angle often give rise either to static changes in the magnitude of electronic coupling along the bridge length or to dynamic fluctuations of this quantity on the certain characteristic time scale τrot. These lead to the functional breakdown of the Condon approximation. Modeling of CT beyond the Condon approximation reveals two types of non-Condon (NC) effects. If τrot is much less than the characteristic time, τCT of CT in the absence of disorder, the NC effects was shown to be static. Due to self-averaging of electronic coupling in this fast fluctuation limit, the breakdown of the Condon approximation manifests itself as a static correction to the time-independent rate coefficient calculated for the ordered bridge with the same time-averaged electronic coupling for all pairs of adjacent subunits. As a consequence, the CT process exponentially evolves with time and therefore can be characterized by a time-independent rate coefficient wa for the charge arrival on the acceptor (also termed the rate constant). For larger τrot, however, the NC effects become purely kinetic. In this case, the process of CT in the tunneling regime exhibits time scale invariance, the corresponding decay curves become dispersive, and the rate coefficient wa turns out to be time dependent. In the limit of very slow dynamic fluctuations, where τrot ≫ τCT, the NC effects in kinetics of CT are found (as anticipated) to be very similar to the effects revealed for bridges with the static torsional disorder. Both analytical and numerical results obtained within this limit allow the conclusion that for very slow fluctuations and/or for static disorder, the nonexponential time evolution of the CT process is due to the configuration averaging of electronic coupling. Several consequences of our theoretical findings for the interpretation of experimentally observed transients are briefly discussed. In particular, we argue that the minimal value of the falloff parameter describing the distance dependence of the time-independent rate coefficient in tunneling regime can not be less than 0.2-0.3 Å-1 and that the smaller experimental value of this parameter reported in the literature for several D-B-A systems must be attributed to the multistep hopping mechanism of charge motion rather than to the mechanism of single-step tunneling.

AB - The influence of static and dynamic torsional disorder on the kinetics of charge transfer (CT) in donorbridge-acceptor (D-B-A) systems has been investigated theoretically using a simple tight-binding model. In such systems, variations of the torsion angle often give rise either to static changes in the magnitude of electronic coupling along the bridge length or to dynamic fluctuations of this quantity on the certain characteristic time scale τrot. These lead to the functional breakdown of the Condon approximation. Modeling of CT beyond the Condon approximation reveals two types of non-Condon (NC) effects. If τrot is much less than the characteristic time, τCT of CT in the absence of disorder, the NC effects was shown to be static. Due to self-averaging of electronic coupling in this fast fluctuation limit, the breakdown of the Condon approximation manifests itself as a static correction to the time-independent rate coefficient calculated for the ordered bridge with the same time-averaged electronic coupling for all pairs of adjacent subunits. As a consequence, the CT process exponentially evolves with time and therefore can be characterized by a time-independent rate coefficient wa for the charge arrival on the acceptor (also termed the rate constant). For larger τrot, however, the NC effects become purely kinetic. In this case, the process of CT in the tunneling regime exhibits time scale invariance, the corresponding decay curves become dispersive, and the rate coefficient wa turns out to be time dependent. In the limit of very slow dynamic fluctuations, where τrot ≫ τCT, the NC effects in kinetics of CT are found (as anticipated) to be very similar to the effects revealed for bridges with the static torsional disorder. Both analytical and numerical results obtained within this limit allow the conclusion that for very slow fluctuations and/or for static disorder, the nonexponential time evolution of the CT process is due to the configuration averaging of electronic coupling. Several consequences of our theoretical findings for the interpretation of experimentally observed transients are briefly discussed. In particular, we argue that the minimal value of the falloff parameter describing the distance dependence of the time-independent rate coefficient in tunneling regime can not be less than 0.2-0.3 Å-1 and that the smaller experimental value of this parameter reported in the literature for several D-B-A systems must be attributed to the multistep hopping mechanism of charge motion rather than to the mechanism of single-step tunneling.

UR - http://www.scopus.com/inward/record.url?scp=49149086550&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=49149086550&partnerID=8YFLogxK

U2 - 10.1021/jp801646g

DO - 10.1021/jp801646g

M3 - Article

VL - 112

SP - 10988

EP - 11000

JO - Journal of Physical Chemistry C

JF - Journal of Physical Chemistry C

SN - 1932-7447

IS - 29

ER -