Enhanced sensitivity to and classification of volatile carboxylic acids using arrays of linear poly(ethylenimine)-carbon black composite vapor detectors

Eric S. Tillman, Michael E. Koscho, Robert H. Grubbs, Nathan S Lewis

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

Vapor detectors formed from composites of conductors and insulating organic polymers have been tailored to produce increased sensitivity toward specific classes of analyte vapors. Upon exposure to acetic acid at 1% of its vapor pressure, detectors consisting of linear poly(ethylenimine) (1-PEI)-carbon black composites showed an ∼103 increase in signal/noise relative to the performance of typical insulating organic polymer-carbon black composite vapor detectors. Compositional diversity in an array of such vapor detectors was obtained by varying the degree of plasticization of the 1-PEI films. The resulting vapor detector array produced sensitive detection of, and robust discrimination between, various volatile organic acids and relatively little response from nonacidic organic vapors or from water vapor. Measurements of the mass uptake, thickness change, and electrical conductivity of such composites indicate that swelling of the polymer film, and thus its normalized resistance response, is beyond that expected by mass uptake alone upon exposure to acetic acid vapor. This additional thickness increase is attributed to charge-induced polymer swelling occurring from polymer-analyte interactions. Electrical percolation also plays a significant role in producing the large increase in normalized resistance response of these composites upon exposure to acetic acid vapor.

Original languageEnglish
Pages (from-to)1748-1753
Number of pages6
JournalAnalytical Chemistry
Volume75
Issue number7
DOIs
Publication statusPublished - Apr 1 2003

Fingerprint

Soot
Carboxylic Acids
Vapors
Detectors
Composite materials
Acetic Acid
Polyetherimides
Organic polymers
Swelling
Polymers
aziridine
Organic acids
Steam
Vapor pressure
Polymer films

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Enhanced sensitivity to and classification of volatile carboxylic acids using arrays of linear poly(ethylenimine)-carbon black composite vapor detectors. / Tillman, Eric S.; Koscho, Michael E.; Grubbs, Robert H.; Lewis, Nathan S.

In: Analytical Chemistry, Vol. 75, No. 7, 01.04.2003, p. 1748-1753.

Research output: Contribution to journalArticle

@article{a6263ec4cc68445fad556d56117b02f6,
title = "Enhanced sensitivity to and classification of volatile carboxylic acids using arrays of linear poly(ethylenimine)-carbon black composite vapor detectors",
abstract = "Vapor detectors formed from composites of conductors and insulating organic polymers have been tailored to produce increased sensitivity toward specific classes of analyte vapors. Upon exposure to acetic acid at 1{\%} of its vapor pressure, detectors consisting of linear poly(ethylenimine) (1-PEI)-carbon black composites showed an ∼103 increase in signal/noise relative to the performance of typical insulating organic polymer-carbon black composite vapor detectors. Compositional diversity in an array of such vapor detectors was obtained by varying the degree of plasticization of the 1-PEI films. The resulting vapor detector array produced sensitive detection of, and robust discrimination between, various volatile organic acids and relatively little response from nonacidic organic vapors or from water vapor. Measurements of the mass uptake, thickness change, and electrical conductivity of such composites indicate that swelling of the polymer film, and thus its normalized resistance response, is beyond that expected by mass uptake alone upon exposure to acetic acid vapor. This additional thickness increase is attributed to charge-induced polymer swelling occurring from polymer-analyte interactions. Electrical percolation also plays a significant role in producing the large increase in normalized resistance response of these composites upon exposure to acetic acid vapor.",
author = "Tillman, {Eric S.} and Koscho, {Michael E.} and Grubbs, {Robert H.} and Lewis, {Nathan S}",
year = "2003",
month = "4",
day = "1",
doi = "10.1021/ac020412l",
language = "English",
volume = "75",
pages = "1748--1753",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "7",

}

TY - JOUR

T1 - Enhanced sensitivity to and classification of volatile carboxylic acids using arrays of linear poly(ethylenimine)-carbon black composite vapor detectors

AU - Tillman, Eric S.

AU - Koscho, Michael E.

AU - Grubbs, Robert H.

AU - Lewis, Nathan S

PY - 2003/4/1

Y1 - 2003/4/1

N2 - Vapor detectors formed from composites of conductors and insulating organic polymers have been tailored to produce increased sensitivity toward specific classes of analyte vapors. Upon exposure to acetic acid at 1% of its vapor pressure, detectors consisting of linear poly(ethylenimine) (1-PEI)-carbon black composites showed an ∼103 increase in signal/noise relative to the performance of typical insulating organic polymer-carbon black composite vapor detectors. Compositional diversity in an array of such vapor detectors was obtained by varying the degree of plasticization of the 1-PEI films. The resulting vapor detector array produced sensitive detection of, and robust discrimination between, various volatile organic acids and relatively little response from nonacidic organic vapors or from water vapor. Measurements of the mass uptake, thickness change, and electrical conductivity of such composites indicate that swelling of the polymer film, and thus its normalized resistance response, is beyond that expected by mass uptake alone upon exposure to acetic acid vapor. This additional thickness increase is attributed to charge-induced polymer swelling occurring from polymer-analyte interactions. Electrical percolation also plays a significant role in producing the large increase in normalized resistance response of these composites upon exposure to acetic acid vapor.

AB - Vapor detectors formed from composites of conductors and insulating organic polymers have been tailored to produce increased sensitivity toward specific classes of analyte vapors. Upon exposure to acetic acid at 1% of its vapor pressure, detectors consisting of linear poly(ethylenimine) (1-PEI)-carbon black composites showed an ∼103 increase in signal/noise relative to the performance of typical insulating organic polymer-carbon black composite vapor detectors. Compositional diversity in an array of such vapor detectors was obtained by varying the degree of plasticization of the 1-PEI films. The resulting vapor detector array produced sensitive detection of, and robust discrimination between, various volatile organic acids and relatively little response from nonacidic organic vapors or from water vapor. Measurements of the mass uptake, thickness change, and electrical conductivity of such composites indicate that swelling of the polymer film, and thus its normalized resistance response, is beyond that expected by mass uptake alone upon exposure to acetic acid vapor. This additional thickness increase is attributed to charge-induced polymer swelling occurring from polymer-analyte interactions. Electrical percolation also plays a significant role in producing the large increase in normalized resistance response of these composites upon exposure to acetic acid vapor.

UR - http://www.scopus.com/inward/record.url?scp=0037374833&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037374833&partnerID=8YFLogxK

U2 - 10.1021/ac020412l

DO - 10.1021/ac020412l

M3 - Article

VL - 75

SP - 1748

EP - 1753

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 7

ER -