Influence of absorption on quantitative analysis in Raman spectroscopy

Zili Wu, Chao Zhang, Peter C Stair

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Absorption of both the excitation and Raman scattered light by the sample (self-absorption) is common in UV Raman spectroscopy and sometimes in visible and FT-Raman spectroscopy due to electronic or vibrational excitation. Self-absorption affects Raman bands and usually results in a non-linear relationship between the Raman intensity and sample concentration. This paper compares quantitative analysis methods for Raman measurements of absorbing liquid and solid samples. Methods based on both internal and external standards can be used to correct for self-absorption. Examples including both liquid (1-methylnaphthalene/isooctane) and solid (V/δ-Al2O 3) systems were used to compare the effectiveness of these methods. The results show that as long as certain restrictions on the use of these analysis methods are satisfied, the self-absorption problem in Raman spectroscopy can be accurately corrected.

Original languageEnglish
Pages (from-to)40-47
Number of pages8
JournalCatalysis Today
Volume113
Issue number1-2
DOIs
Publication statusPublished - Mar 30 2006

Fingerprint

Raman spectroscopy
Chemical analysis
Liquids
Ultraviolet spectroscopy
2,2,4-trimethylpentane
1-methylnaphthalene

Keywords

  • Absorption
  • Correction
  • Diffuse reflectance
  • External standard
  • Internal standard
  • Quantitative analysis
  • Raman spectroscopy
  • Scattering

ASJC Scopus subject areas

  • Catalysis
  • Process Chemistry and Technology

Cite this

Influence of absorption on quantitative analysis in Raman spectroscopy. / Wu, Zili; Zhang, Chao; Stair, Peter C.

In: Catalysis Today, Vol. 113, No. 1-2, 30.03.2006, p. 40-47.

Research output: Contribution to journalArticle

Wu, Zili ; Zhang, Chao ; Stair, Peter C. / Influence of absorption on quantitative analysis in Raman spectroscopy. In: Catalysis Today. 2006 ; Vol. 113, No. 1-2. pp. 40-47.
@article{3137a1fd645b440799475edf0af39eb5,
title = "Influence of absorption on quantitative analysis in Raman spectroscopy",
abstract = "Absorption of both the excitation and Raman scattered light by the sample (self-absorption) is common in UV Raman spectroscopy and sometimes in visible and FT-Raman spectroscopy due to electronic or vibrational excitation. Self-absorption affects Raman bands and usually results in a non-linear relationship between the Raman intensity and sample concentration. This paper compares quantitative analysis methods for Raman measurements of absorbing liquid and solid samples. Methods based on both internal and external standards can be used to correct for self-absorption. Examples including both liquid (1-methylnaphthalene/isooctane) and solid (V/δ-Al2O 3) systems were used to compare the effectiveness of these methods. The results show that as long as certain restrictions on the use of these analysis methods are satisfied, the self-absorption problem in Raman spectroscopy can be accurately corrected.",
keywords = "Absorption, Correction, Diffuse reflectance, External standard, Internal standard, Quantitative analysis, Raman spectroscopy, Scattering",
author = "Zili Wu and Chao Zhang and Stair, {Peter C}",
year = "2006",
month = "3",
day = "30",
doi = "10.1016/j.cattod.2005.11.077",
language = "English",
volume = "113",
pages = "40--47",
journal = "Catalysis Today",
issn = "0920-5861",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - Influence of absorption on quantitative analysis in Raman spectroscopy

AU - Wu, Zili

AU - Zhang, Chao

AU - Stair, Peter C

PY - 2006/3/30

Y1 - 2006/3/30

N2 - Absorption of both the excitation and Raman scattered light by the sample (self-absorption) is common in UV Raman spectroscopy and sometimes in visible and FT-Raman spectroscopy due to electronic or vibrational excitation. Self-absorption affects Raman bands and usually results in a non-linear relationship between the Raman intensity and sample concentration. This paper compares quantitative analysis methods for Raman measurements of absorbing liquid and solid samples. Methods based on both internal and external standards can be used to correct for self-absorption. Examples including both liquid (1-methylnaphthalene/isooctane) and solid (V/δ-Al2O 3) systems were used to compare the effectiveness of these methods. The results show that as long as certain restrictions on the use of these analysis methods are satisfied, the self-absorption problem in Raman spectroscopy can be accurately corrected.

AB - Absorption of both the excitation and Raman scattered light by the sample (self-absorption) is common in UV Raman spectroscopy and sometimes in visible and FT-Raman spectroscopy due to electronic or vibrational excitation. Self-absorption affects Raman bands and usually results in a non-linear relationship between the Raman intensity and sample concentration. This paper compares quantitative analysis methods for Raman measurements of absorbing liquid and solid samples. Methods based on both internal and external standards can be used to correct for self-absorption. Examples including both liquid (1-methylnaphthalene/isooctane) and solid (V/δ-Al2O 3) systems were used to compare the effectiveness of these methods. The results show that as long as certain restrictions on the use of these analysis methods are satisfied, the self-absorption problem in Raman spectroscopy can be accurately corrected.

KW - Absorption

KW - Correction

KW - Diffuse reflectance

KW - External standard

KW - Internal standard

KW - Quantitative analysis

KW - Raman spectroscopy

KW - Scattering

UR - http://www.scopus.com/inward/record.url?scp=33344477313&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33344477313&partnerID=8YFLogxK

U2 - 10.1016/j.cattod.2005.11.077

DO - 10.1016/j.cattod.2005.11.077

M3 - Article

VL - 113

SP - 40

EP - 47

JO - Catalysis Today

JF - Catalysis Today

SN - 0920-5861

IS - 1-2

ER -